This part of ISO 717:
a) defines single-number quantities for impact sound insulation in buildings and of floors;
b) gives rules for determining these quantities from the results of measurements carried out in one-third-octave bands in accordance with ISO 10140-3 and ISO 140-7, and in octave bands in accord-ance with that option in ISO 140-7 for field measurements only;
c) defines single-number quantities for the impact sound reduction of floor coverings and floating floors calculated from the results of measurements carried out in accordance with ISO 10140-3;
d) specifies a procedure for evaluating the weighted reduction in impact sound pressure level by floor coverings on lightweight floors.