ISO 3452-3:2013 describes two types of reference blocks:
— Type 1 reference blocks are used to determine the sensitivity levels of both fluorescent and colour contrast penetrant product families;
— Type 2 reference blocks are used for routine assessment of the performance of both fluorescent and colour contrast penetrant testing.
The reference blocks are to be used in accordance with part 1 of this International Standard.